251 storefront series
2” x 4 1/2” SECTION
ALUMINUM STOREFRONTS PL-251 SERIES
The 251 series introduces an offset glazed system featuring frame/glass faces slightly on plan, ensuring a minimal frame protrusion for heightened aesthetics and performance values. Tailored for seamless integration with 1-inch insulated glass, it comes equipped with a comprehensive range of extrusions and accessories, making it suitable for diverse job conditions. This glazing system, available in 2 x 4-1/2 sections, offers flexibility with glass inserts that can be positioned inward or outward, allowing for customized applications. Additionally, the system is designed to accommodate most PRL Entrance Doors, providing a versatile solution for various architectural needs.
- INSTALATION
- TEST STRUCTURAL
- TEST IMPACT
HANDLING, STORAGE AND PROTECTION OF ALUMINUM
The following precautions are recommended to protect the material against damage.
Following these precautions will help ensure early acceptance of your products and workmanship.
The mockup specimen for testing was a flat wall specimen, nominal one (1) story high, consisting of a 4 1/2″ deep, offset glazed, aluminum window wall system, measuring approx, 10´ wide by 10´ high (3 lites wide by 2 lites high). The system was glazed.
Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). The samples tested met the performance requeriments set forth in the referenced test procedures for a +1676/-2873 Pa (+35/-60psf) Design Pressure with missile impacts corresponding to Missile Level D and Wind Zone 3 for a basic protection rating.
The 251 series introduces an offset glazed system featuring frame/glass faces slightly on plan, ensuring a minimal frame protrusion for heightened aesthetics and performance values. Tailored for seamless integration with 1-inch insulated glass, it comes equipped with a comprehensive range of extrusions and accessories, making it suitable for diverse job conditions. This glazing system, available in 2 x 4-1/2 sections, offers flexibility with glass inserts that can be positioned inward or outward, allowing for customized applications. Additionally, the system is designed to accommodate most PRL Entrance Doors, providing a versatile solution for various architectural needs.
- INSTALATION
- TEST STRUCTURAL
- TEST IMPACT
HANDLING, STORAGE AND PROTECTION OF ALUMINUM
The following precautions are recommended to protect the material against damage.
Following these precautions will help ensure early acceptance of your products and workmanship.
The mockup specimen for testing was a flat wall specimen, nominal one (1) story high, consisting of a 4 1/2″ deep, offset glazed, aluminum window wall system, measuring approx, 10´ wide by 10´ high (3 lites wide by 2 lites high). The system was glazed.
Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). The samples tested met the performance requeriments set forth in the referenced test procedures for a +1676/-2873 Pa (+35/-60psf) Design Pressure with missile impacts corresponding to Missile Level D and Wind Zone 3 for a basic protection rating.
IMAGE CAD BIM
IMAGE CAD BIM
251-Series (2 X 4-1/2 Offset Glaze For 1 Glazing):
Performance: (Test sample of 10 feet (3048 mm) wide by 10 feet (3048 mm) high – 3 lites wide by 2 lites high).
a. Air infiltration:
Limit air leakage through fixed glazing and frames to 0.039 cfm/ft2/min when tested in accordance with ASTM E-283 at a cross pressure of 6.24 psf (0.30 kPa).
b. Water penetration under static pressure:
System shall not evidence uncontrolled water penetration at a cross pressure of 6 psf (0.29 kPa) when tested in accordance with ASTM-E331-00.
c. Uniform load structural per ASTM E 330:
Limit deflection to L/175. 1) Passed at Design Pressure of 20 psf (0.96 kPa).
EXAMINATION
- Do not begin installation until substrates have been properly
- If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
PREPARATION
- Clean surfaces thoroughly prior to
- Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
INSTALLATION
- Install in accordance with manufacturer’s
FIELD QUALITY CONTROL
- All joints between metal and masonry shall be fully caulked and field tested to resist water leakage with provisions taken to drain infiltrated water.
PROTECTION
- Protect installed products until completion of
- Touch-up, repair or replace damaged products before Substantial